Optional accessories for CR-400 / CR-410
Granular Attachment CR-A50
For measurements of powders, pastes, grains or other small sized granular material. The low reflectance glass plate protects the sample surface against disorientation and prevents specimen material to enter the instrument. The set includes one retaining ring each to adjust the measuring area accordingly to either CR-400 or CR-410.
Item Order Code: 1829-751
Glass Plate for CR-A51 (for CR-A50)
Replacement low reflectance glass plate for CR-A50 Granular Attachment.
Item Order Code: 1829-752
Retaining Ring Set CR-A52
Replacement ring set for CR-A50 Granular Attachment. The set consist of one ring each for CR-400 and CR-410.
Item Order Code: 1829-753
Light Protection Tube with glass protection plate CR-A33a (only for CR-400)
Light projection tube for measurement of pasty, wet or moist samples. The convex protection glass plate prevents specimen from entering the instrument. The CR-A33a is recommended for soft specimen. The diameter of the plate is 22 mm.
Item Order Code: 1849-731
Light Protection Tube with Glass Protection CR-A33f (only for CR-400)
Light projection tube for measurement of soft samples. The concave protection glass plate prevents specimen from entering the instrument. The CR-A33a is recommended for flattening soft or soft and wet specimen. The diameter of the plate is 22 mm diameter.
Item Order Code: 1849-736
Specimen Holder CM-A96 (only for CR-400)
Required to fix opaque samples or the Glass or Disposal cells for measurement of opaque liquids in combination with the Sample Holder CR-A505. The clamp provides a constant pressure to the sample and the moveable side holders keep the cells in correct position.
Item Order Code: 1864-708
Glass Cell CR-A504 (only for CR-400)
Cell made of optical glass for measurements of powders, pastes, grains and small granular materials. Diameter of the cell 34 mm. For precise positioning the Cell Holder CR-A503 is recommended.
Item Order Code: 9970-2504
Sample Holder CR-A505 (only for CR-400)
Base holder to set the measuring head in horizontal position. Allows in combination with the Specimen Holder CM-A96 measurements of small samples up to a thickness of 22.5 mm or with the Glass- or Disposal Cells with 10 or 20 mm optical path the measurement of opaque liquids.
Item Order Code: 9970-441
Flow Cell CM-A508 (only for CR-400)
For continuous measurements of opaque liquids in reflectance mode. The optical path of the cell is 10 mm and the max. pressure is up to 2 Bar. For the positioning of the Flow Cell CM-A508 the horizontal aligned Sample Holder CR-A505 and the Sample Holder CM-A96 are required.
Item Order Code: 9970-237
Data Cable CR-A102 RS232c
Connection cable between measuring head or data processor and PC. For PC terminals with 9 pin SUB-D connecter. Length of the cable 2 m.
Item Order Code: 1878-704